Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/18816
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorCamués Buitrón, Carlos Vinicio-
dc.date.accessioned2017-10-04T19:31:32Z-
dc.date.available2017-10-04T19:31:32Z-
dc.date.issued2017-10-04-
dc.identifier.citationCamués Buitrón, C. V. (2017). Diseño de una red de datos y propuesta de plan de contingencia para el cableado estructurado del edificio de la Defensoría Pública del Ecuador de la ciudad de Quito. 121 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4530/CD 8203-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/18816-
dc.descriptionThe project shows the design of the structured cabling system, shows a contingency plan for the Child and Adolescent Building of the Public Defender of Ecuador. It details the ANSI / EIA / TIA 568C, ANSI / EIA / TIA 569 standards used in the design of a structured cabling network, shows concepts and definitions, clearly establishing the guidelines for designing the structured cabling system. An analysis of building requirements is performed for both the data network and the building infrastructure. It shows the contingency plan considering the current reality of the building, identifying the risks to which both the data network and the physical structure of the building are exposed, shows the times and procedures to follow in case of any adverse events that may compromise network and building security.es_ES
dc.description.abstractThe project shows the design of the structured cabling system, shows a contingency plan for the Child and Adolescent Building of the Public Defender of Ecuador. It details the ANSI / EIA / TIA 568C, ANSI / EIA / TIA 569 standards used in the design of a structured cabling network, shows concepts and definitions, clearly establishing the guidelines for designing the structured cabling system. An analysis of building requirements is performed for both the data network and the building infrastructure. It shows the contingency plan considering the current reality of the building, identifying the risks to which both the data network and the physical structure of the building are exposed, shows the times and procedures to follow in case of any adverse events that may compromise network and building security.es_ES
dc.description.sponsorshipCarvajal Rodríguez, Jorge Eduardo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccesses_ES
dc.subjectCOMUNICACIÓNES DIGITALESes_ES
dc.subjectCABLEADO ESTRUCTURADOes_ES
dc.subjectPLANES DE CONTINGENCIAes_ES
dc.titleDiseño de una red de datos y propuesta de plan de contingencia para el cableado estructurado del edificio de la Defensoría Pública del Ecuador de la ciudad de Quitoes_ES
dc.typebachelorThesises_ES