Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/21504
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorAñazco Luzón, Elizabeth Esthefanía-
dc.date.accessioned2021-03-24T17:24:16Z-
dc.date.available2021-03-24T17:24:16Z-
dc.date.issued2021-03-11-
dc.identifier.citationAñazco Luzón, E. E. (2021). Análisis del funcionamiento de la protección de sobrecorriente direccional de líneas de transmisión ante corrientes evolutivas de cortocircuito. 85 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE 5167/CD 10997-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/21504-
dc.descriptionCon la realización del presente trabajo de titulación se dispone de una herramienta computacional que facilita el análisis del comportamiento de las protecciones de sobrecorriente de líneas de transmisión, ya sea cuando se presenten fallas convencionales o cortocircuitos con corrientes evolutivas. De esta manera, esta herramienta puede evidenciar si la operación de las protecciones mencionadas fue incorrecta o si por el contrario dicha operación se mantuvo dentro del funcionamiento esperado, considerando su parametrización y ajuste. Como un elemento adicional para el análisis, y considerando las características de las protecciones de sobrecorriente instaladas en líneas de transmisión, se desarrolló una rutina que permite visualizar la zona de operación direccional establecida con el método de polarización parametrizado en los relés.es_ES
dc.description.abstractWith the completion of this titration work, a computational tool is available that facilitates the analysis of the behavior of the overcurrent protections of transmission lines, either when conventional faults or short circuits with evolving currents occur. In this way, this tool can show if the operation of the mentioned protections was incorrect or if, on the contrary, said operation remained within the expected operation, considering its parameterization and adjustment. As an additional element for the analysis, and considering the characteristics of the overcurrent protections installed in transmission lines, a routine was developed that allows visualizing the directional operating zone established with the polarization method parameterized in the relays.es_ES
dc.description.sponsorshipPérez Yauli, Fabian Ernesto, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2021.es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectLÍNEAS DE TRANSMISIÓNes_ES
dc.subjectCORRIENTES EVOLUTIVASes_ES
dc.subjectRELÉ DIRECCIONALes_ES
dc.titleAnálisis del funcionamiento de la protección de sobrecorriente direccional de líneas de transmisión ante corrientes evolutivas de cortocircuitoes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 10997.pdf2,74 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.