dc.identifier.citationPaucar Cordova, K. A. (2019). Evaluación del aislamiento de una línea de transmisión de 500 kV ante descargas atmosféricas utilizando un método estadístico. 105 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4824/CD 9422-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/19970-
dc.descriptionEn el presente estudio se realizó la evaluación del desempeño de la cadena de aisladores de una línea de transmisión de 500 kV ante el impacto de descargas atmosféricas mediante un método estadístico. Este método consiste en determinar la probabilidad de falla del aislamiento de una línea de transmisión al ser impactada por un rayo. Para ello se desarrolló una rutina en MATLAB que realiza la simulación sistemática del impacto por separado de miles de rayos. La simulación de transitorios electromagnéticos en ATP permitió determinar el comportamiento de la línea de transmisión ante una descarga atmosférica considerando el efecto de todos los elementos eléctricos involucrados en este fenómeno, la naturaleza aleatoria del rayo y cuatro diferentes puntos de impacto. Resultado de las simulaciones se obtiene la densidad de los sobrevoltajes, esta función en conjunto con aquella que representa la rigidez dieléctrica del aislamiento permiten aplicar el método propuesto con el fin de determinar la probabilidad de falla del aislamiento o riesgo de ruptura del aislamiento. Finalmente, la evaluación del aislamiento se lleva al cabo al verificar si el riesgo de ruptura del aislamiento de la línea cumple con los criterios de confiabilidad que rigen en el país.es_ES
dc.description.abstractThe lightning performance evaluation of a 500 kV transmission line insulation using a statistical method; which is based on the calculation of the risk of insulation failure. In order to calculate the mentioned risk a systematic simulation of the impact of ten thousand downward negative lightning was developed. At first, overvoltage density curves were statistical estimated from these simulations. The ATP transmission line model has considered all electrical elements involved in this phenomenon, the random nature of lightning and four different stroke locations. It must be pointed out that lightning current parameters were represented by aleatory numerical data generated according to the originated density functions from direct stroke current measurements performed in several countries. Moreover, the stroke location was determinated by applying the electro geometric model. Second, insulation was represented taking account its dielectric strength statistical behavior. Then, the risk of failure of line insulation is calculate. Finally, the insulation evaluation is performed by verifying if the risk of failure of line insulation meets the reliability criteria that applies in our country.es_ES
dc.description.sponsorshipPérez Yauli, Fabián Ernesto, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2019es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectDISEÑO EN ALTO VOLTAJEes_ES
dc.subjectDISEÑO ELECTROMECÁNICOes_ES
dc.titleEvaluación del aislamiento de una línea de transmisión de 500 kV ante descargas atmosféricas utilizando un método estadísticoes_ES