Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/21088
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorCachago Lluglluna, Marco Giovanny-
dc.date.accessioned2020-09-08T16:15:02Z-
dc.date.available2020-09-08T16:15:02Z-
dc.date.issued2020-09-03-
dc.identifier.citationCachago Lluglluna, M. G. (2020). Diseño y construcción de un sistema de refrigeración didáctico para enfriamiento de agua (Chiller). 67 hojas. Quito : EPN.es_ES
dc.identifier.otherT-TEM/0222/CD 10599-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/21088-
dc.descriptionEn el proyecto se implementó un módulo didáctico de un sistema de refrigeración para enfriamiento de agua (chiller) para la utilización y el manejo por parte de los estudiantes de la Carrera de Tecnología en Electromecánica en el Laboratorio de Tecnología Industrial. Para el diseño de la cámara y la selección de los componentes del sistema de refrigeración, se calculó la carga térmica del sistema con base a los criterios de: trasmisión de calor a través de paredes, carga del producto (agua), carga de servicio y factor de seguridad. Se determinó que la carga térmica fue de 0.854 [kW] y posteriormente, se analizó el ciclo termodinámico de refrigeración por compresión de vapor utilizando R134a. En base a los cálculos se seleccionó el compresor 1/3 de [HP] para enfriar 13 litros de agua en 30 minutos. La selección del evaporador, condensador y válvula de expansión se realizó en base a la dimensión del compresor. Se realizó pruebas de funcionamiento de la cámara en vacío y con el volumen de agua calculado. El sistema tardó aproximadamente 36 minutos en enfriar agua de 25 [°C] a 5 [°C]. La presión de condensación del sistema cuando el compresor se encuentra encendido fue de 148 [psi] y la presión de evaporación fue de 29 [psi] lo que verifica que el sistema se encuentra funcionando correctamente.es_ES
dc.description.abstractIn the project, a didactic module of a cooling system for water cooling (chiller) was implemented for the use and handling by the students of the carrer of Electromechanical Technology of the ESFOT-EPN. For the design of the chiller and the selection of the components of the cooling system, the thermal load of the system was calculated based on: heat transmission through walls, product load (water), service load and safety factor. It was determined that the thermal load was 0.854 [kW] and then, the thermodynamic cycle of refrigeration by vapor compression was analyzed using R134a. Based on the calculations, the compressor of 1/3 [HP] was to cool 13 liters of water in 30 minutes. The selection of the evaporator, condenser and expansion valve was done considering the size of the compressor. The operation of the system was tested without water (without load) and with the calculated volume of water. The system took approximately 36 minutes to cool water from 25 [°C] to 5 [°C]. When the compressor was working, the condensation pressure of the system was 148 [psi] and the evaporation pressure was 29 [psi], which verifies that the system is working properly.es_ES
dc.description.sponsorshipZúñiga Puebla, Hugo Francisco, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2020.es_ES
dc.rightsopenAccesses_ES
dc.subjectSISTEMAS DE REFRIGERACIÓNes_ES
dc.subjectAGUAes_ES
dc.subjectENFRIADORes_ES
dc.titleDiseño y construcción de un sistema de refrigeración didáctico para enfriamiento de agua (Chiller)es_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Electromecánica (EM)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 10599.pdf2,11 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.