Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/22504
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorGarzón Rubio, Josué Ariel-
dc.date.accessioned2022-05-31T19:42:17Z-
dc.date.available2022-05-31T19:42:17Z-
dc.date.issued2022-02-
dc.identifier.citationGarzón Rubio, J. A. (2022). Exoesqueleto potenciador de fuerza para la mano. 58 páginas. Quito : EPN.es_ES
dc.identifier.otherT-IM/2269/CD 12003-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/22504-
dc.descriptionEl componente de trabajo realizado busca implantar un estudio preliminar que permita la evaluación de la fuerza de agarre desarrollada por la mano junto con la incorporación de un prototipo de exoesqueleto previamente seleccionado. La intención es establecer a la fuerza de agarre como un parámetro fundamental que se debe tomar en cuenta para la validación funcional de prototipos de exoesqueletos destinados para áreas como: medicina rehabilitación física, salud y seguridad ocupacional. Para lograrlo, se definió un diseño de exoesqueleto para la mano haciendo uso de la función de la calidad, se propuso diseños conceptuales aplicando herramientas presentes en el diseño concurrente y se seleccionó la mejor alternativa para su prototipado mediante la incorporación de métodos multicriterio para la toma de decisiones. Una vez materializado el exoesqueleto se procede junto al sujeto colaborador a la ejecución de pruebas experimentales para registrar la fuerza de agarre cilíndrico de potencia, además de, detectar fallos cometidos en el procedimiento. La realización de pruebas experimentales piloto confirmó fallos cometidos y parámetros no considerados en el procedimiento. Con esto, se adoptó medidas correctivas para la elaboración de un protocolo de pruebas, garantizando un procedimiento reproducible y confiable en el proceso de medición de fuerza del agarre cilíndrico de potencia.es_ES
dc.description.abstractThe work component carried out seeks to implement a preliminary study that allows the evaluation of the grip strength developed by the hand together with the incorporation of a previously selected exoskeleton prototype. The intention is to establish grip strength as a fundamental parameter that must be taken into account for the functional validation of exoskeleton prototypes intended for areas of medicine, physical rehabilitation, health and occupational safety. To achieve this, an exoskeleton design for the hand was defined using the quality function, conceptual designs were proposed by applying tools present in the concurrent design, and the best alternative was selected for prototyping by incorporating multicriteria methods for decision-making. of decisions. Once the exoskeleton materialized, the collaborating subject proceeded to carry out experimental tests to record the power cylindrical grip force, in addition to detecting errors made in the procedure. Carrying out pilot experimental tests confirmed mistakes made and parameters not considered in the procedure. With this, corrective measures were adopted for the elaboration of a test protocol, guaranteeing a reproducible and reliable procedure in the force measurement process of the cylindrical power grip.es_ES
dc.description.sponsorshipVenegas Toro, William Ricardo, director.es_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2022es_ES
dc.rightsopenAccesses_ES
dc.subjectEXOESQUELETO MANOes_ES
dc.subjectREHABILITACIÓN MÉDICAes_ES
dc.subjectBIOMECÁNICAes_ES
dc.subjectPROTOCOLO DE PRUEBASes_ES
dc.titleExoesqueleto potenciador de fuerza para la mano.es_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:TIC - Mecánica

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 12003.pdf2,66 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.