Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/24979
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorSinchi Rea, David Gabrieli-
dc.contributor.editorValencia Arcos, Fausto Ramiro-
dc.date.accessioned2023-10-31T15:08:10Z-
dc.date.available2023-10-31T15:08:10Z-
dc.date.issued2023-10-11-
dc.identifier.citationSinchi Rea, D.G.(2023).Pruebas en cables subterráneos : Análisis del estado actual de las pruebas de diagnóstico y localización de fallas en cables subterráneos utilizando el Laboratorio Móvil de Cables Centrix 2.0 de la Empresa Eléctrica Quito S.A.167 páginas. Quito : EPN.es_ES
dc.identifier.otherT-IE/5835/CD 13727-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/24979-
dc.descriptionAnálisis del estado actual de las pruebas de diagnóstico y localización de fallas en cables subterráneos utilizando el Laboratorio Móvil de Cables Centrix 2.0 de la Empresa Eléctrica Quito S.A.es_ES
dc.description.abstractThis Curricular Integration Work consists of the elaboration of a Technical Guide for the execution of diagnostic and fault location field tests in medium voltage underground cable systems. It describes the test procedures for installation, acceptance and maintenance, as well as the procedure for locating high impedance faults, applied through the Megger Centrix test system installed in the Mobile Cable Laboratory of Empresa Eléctrica Quito. For this purpose, the corresponding international standards IEEE 400.2-2013 and IEC 60229-2007 for the application of diagnostic tests with high voltage DC and AC VLF, and the IEEE 1234-2019 standard for fault location in shielded cable systems are referenced. Which provide standardized test parameters and methodologies, as well as acceptance criteria, evaluation and interpretation of results. In addition, this document considers and describes the safety procedures and the procedures that precede the application of high voltage field tests. It also describes the equipment and the operation of the Centrix test system. Moreover, it includes the application of real field tests. The structure of the Technical Test Guide consists of components such as objectives, equipment, regulations, execution procedures and acceptance or evaluation criteria that allow its proper interpretation and reading, so that the final technician or operator can apply the respective tests, step by step, using Megger test equipment, specifically, the Centrix test system.es_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2023.es_ES
dc.rightsopenAccesses_ES
dc.subjectELECTRICIDADes_ES
dc.subjectPRUEBAS DE CAMPO EN CABLESes_ES
dc.subjectDIAGNÓSTICO EN CABLES AISLADOSes_ES
dc.subjectLOCALIZACIÓN DE FALLAS EN CABLESes_ES
dc.subjectLABORATORIO MÓVIL DE CABLESes_ES
dc.subjectSISTEMA DE PRUEBAS CENTRIXes_ES
dc.titlePruebas en cables subterráneos : Análisis del estado actual de las pruebas de diagnóstico y localización de fallas en cables subterráneos utilizando el Laboratorio Móvil de Cables Centrix 2.0 de la Empresa Eléctrica Quito S.A.es_ES
dc.typeTrabajo de Integración Curriculares_ES
Aparece en las colecciones:TIC - Electricidad (FIEE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 13727.pdf12,25 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.