Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/25940
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorGuzmán Castillo, Adán Francisco-
dc.contributor.editorIntriago Pazmiño, María Monserratees_ES
dc.date.accessioned2024-10-23T15:59:32Z-
dc.date.available2024-10-23T15:59:32Z-
dc.date.issued2024-08-
dc.identifier.citationGuzmán Castillo, A.F. (2024). Detección automática del disco óptico en retinografías digitales patológicas. 62 páginas. Quito : EPN.es_ES
dc.identifier.otherT-MVE 1179/CD 14850-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/25940-
dc.descriptionEn el presente trabajo se estudian técnicas de visión artificial para la detección del disco óptico (DO) en imágenes médicas con patología de fondo de ojo. Este estudio incluye el análisis de imágenes de cuatro conjuntos de imágenes públicos utilizados en otras investigaciones científicas. Se implementan correcciones de nitidez, contraste, ecualización de histograma adaptativo limitado por contraste (CLAHE). Finalmente, se ejecuta la métrica de entropía para determinar según su resultado, la localización del disco óptico en un bloque candidato. Se proponen dos métodos de localización del DO que permitirán localizarlo de forma cuantitativa en los dos casos. El primer método localizará el DO en dos etapas dividiendo la imagen en 9 bloques y en ventanas deslizantes; el bloque con mayor entropía será en donde se encuentre el disco óptico. El segundo método localizará el DO directamente a través de cinco ventanas deslizantes; el bloque candidato será el que tenga mayor entropía y donde estará localizado el DO. Las pruebas permiten comprobar que la métrica de Entropía proporciona resultados que permiten localizar, de forma cuantitativa, el disco óptico de la mayoría de las imágenes; los mejores resultados para el primer método fueron del 96.08% en Drishti-GS Test y para el segundo método fueron de 91.84% en Drishti-GS Training. La métrica Entropía es aplicada en cada región de la imagen. El tamaño del bloque ha sido previamente determinado, y se puede concluir experimentalmente que la obtención de mejores resultados se consigue con nueve bloques de igual tamaño en la imagen analizada.es_ES
dc.description.abstractIn the current work, machine vision techniques for optic disc (OD) detection in medical images with fundus pathology are studied. This study includes the analysis of images from four public image sets used in other scientific investigations. Sharpness, contrast, contrast limited adaptive histogram equalization (CLAHE) corrections are implemented. Finally, the Entropy metric is run to determine according to its result, the location of the optical disk in a candidate block. Two methods of OD localization are proposed that will allow to locate the optical disc quantitatively in the two cases. The first method will locate the OD in two stages by dividing the image into 9 blocks and sliding windows; the block with the highest entropy will be the one where the optical disk is located. The second method will locate the OD directly through five sliding windows; the candidate block will be the one with the highest entropy and that is where the OD will be located. The tests allow to verify that the Entropy metric provides results that allow to locate, in a quantitative way, the optical disk of most of the images; the best results for the first method were 96.08% in Drishti-GS Test and for the second method were 91.84% in DrishtiGS Training. The Entropy metric is applied to each region of the image. The block size has been previously determined, and it can be experimentally concluded that the best results are obtained with nine blocks of equal size along the analyzed image.es_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2024.es_ES
dc.rightsopenAccesses_ES
dc.subjectSISTEMA INFORMÁTICOes_ES
dc.subjectINTELIGENCIA ARTIFICIALes_ES
dc.subjectDISCO ÓPTICOes_ES
dc.subjectENTROPÍAes_ES
dc.subjectVENTANA DESLIZANTEes_ES
dc.subjectREPROCESAMIENTOes_ES
dc.titleDetección automática del disco óptico en retinografías digitales patológicas.es_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Maestría en Computación Mención en Sistemas Inteligentes

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 14850.pdf3,03 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.