Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/21041
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorPérez Sancho, Miguel Alejandro-
dc.date.accessioned2020-08-19T22:58:23Z-
dc.date.available2020-08-19T22:58:23Z-
dc.date.issued2020-08-11-
dc.identifier.citationPérez Sancho, M. A. (2020). Análisis de riesgo ergonómico inherente a la actividad del baño de neonatos desempeñada por enfermeras utilizando la metodología REBA a través de sensores de profundidad Kinect. 90 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IM/2125/CD 10556-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/21041-
dc.descriptionLa inexistencia de parámetros cuantitativos para determinar la movilidad de los segmentos corporales requeridos por las escalas de valoración funcional como REBA (Rapid Entire Boddy Assessment) reducen su fiabilidad al identificar riesgos fundamentados solamente en la observación postural. El presente trabajo analiza el riesgo ergonómico asociado a la actividad de baño de neonatos desempeñada por enfermeras, la influencia de la introducción de sensores Kinect y su función de seguimiento esquelético sin marcadores en conjunto con la herramienta de análisis postural REBA en la reducción de la variabilidad inter-observador y la subjetividad de los resultados. 5 participantes sin lesiones reprodujeron la secuencia movimientos del lavado de cuerpo de un bebé, seleccionada como la más crítica dentro de la actividad. El uso de un sistema de captura de movimiento de referencia (fotogrametría), se utilizó para comprobar la validez de Kinect como instrumento de medida y su precisión. Variables como la frecuencia de grabación de los sensores, y su localización con respecto a los participantes, influyen en la detección de posiciones corporales. La postura analizada está asociado un riesgo ergonómico de nivel intermedio y requiere intervención.es_ES
dc.description.abstractThe absence of quantitative parameters to determine the mobility of the body segments required by functional assessment scales such as REBA (Rapid Entire Boddy Assessment) reduce its reliability by identifying risks based only on postural observation. The present work analyzes the ergonomic risk associated with neonatal bathing activity performed by nurses, the influence of the introduction of Kinect sensors and their marker-less skeleton tracking function in conjunction with the postural analysis tool REBA to reduce the inter-observer variability and the subjectivity of the results. 5 participants without injuries reproduced the sequence of movements of a baby's body wash task, selected as the most critical within the activity. The use of a reference motion capture system (photogrammetry) was used to check the validity of Kinect as a measurement instrument and its precision. Variables such as the recording frequency of the sensors, and their location with respect to the participants, influence the detection of body positions. The analyzed posture is associated with an intermediate level of ergonomic risk and requires intervention.es_ES
dc.description.sponsorshipZambrano Orejuela, Oscar Iván, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2020.es_ES
dc.rightsopenAccesses_ES
dc.subjectRIESGO ECONÓMICOes_ES
dc.subjectSENSORESes_ES
dc.subjectVALORACIÓN FUNCIONALes_ES
dc.titleAnálisis de riesgo ergonómico inherente a la actividad del baño de neonatos desempeñada por enfermeras utilizando la metodología REBA a través de sensores de profundidad Kinectes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Mecánica (IM)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 10556.pdf3,32 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.