Por favor, use este identificador para citar o enlazar este ítem:
http://bibdigital.epn.edu.ec/handle/15000/25588
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Almachi Almachi, Angie Pamela | - |
dc.contributor.editor | Vásquez Falcones, Eduardo Mauricio | - |
dc.date.accessioned | 2024-05-20T18:57:15Z | - |
dc.date.available | 2024-05-20T18:57:15Z | - |
dc.date.issued | 2024-02 | - |
dc.identifier.citation | Almachi Almachi, A.P. (2024). Evaluación hidráulica de las redes de distribución del sistema de abastecimiento de la comuna Chinchiloma : evaluación hidráulica de la red de distribución del barrio "Sector 3". 42 páginas. Quito : EPN. | es_ES |
dc.identifier.other | T-TASA 0184/CD 14099 | - |
dc.identifier.uri | http://bibdigital.epn.edu.ec/handle/15000/25588 | - |
dc.description | El presente componente aborda la evaluación hidráulica de la red de distribución del “Sector 3”, como parte del proyecto de Evaluación hidráulica de las redes de distribución del sistema de abastecimiento de la comuna Chinchiloma en la parroquia de Santa Rosa de Cuzubamba. Para la recopilación de datos existentes del sistema primario de abastecimiento del barrio “Sector 3”, se levantó la información topográfica de la línea de distribución en donde fue necesario el apoyo del operador de la Planta de Tratamiento de Agua Potable (PTAP) para que especifique los puntos de interés que se encontraban a lo largo de la red. Posteriormente, se evaluó hidráulicamente la infraestructura de las redes, mediante software especializado. Al realizarse la línea de distribución se establecieron nodos de los puntos de interés y nodos extras para comprobar la presión en el modelo estático y dinámico y velocidades. Adicionalmente, se realizó el cálculo de caudales de consumo para cada tramo de tubería y adicionalmente el caudal máximo horario, caudal máximo diario y caudal medio. Se ejecutó el aforo de caudales de la tubería que sale del tanque de almacenamiento que contenía un volumen de 40 m^3, con la finalidad de obtener una curva de consumo para identificar posibles fallas en la red. Por último, se propuso mejoras con base en los resultados de la evaluación hidráulica, tomando en cuenta la normativa de la Empresa Metropolitana de Alcantarillado y Agua Potable de Quito (EPMAP-Q), con la realización de dos planos que contengan la línea de distribución actual y la línea con la propuesta de mejoras realizada que consistió en la colocación de válvulas reguladoras de presión en puntos estratégicos, con el fin de garantizar un suministro de agua eficiente. | es_ES |
dc.description.abstract | This component addresses the hydraulic evaluation of the distribution network of “Sector 3”, as part of the project for Hydraulic Evaluation of the distribution networks of the supply system of the Chinchiloma commune in the parish of Santa Rosa de Cuzubamba. For the collection of existing data from the primary supply system of the “Sector 3” neighborhood, topographic information was collected from the distribution line where the support of the operator of the Drinking Water Treatment Plant (PTAP) was necessary to specify the points of interest that were along the network. Subsequently, the network infrastructure was evaluated hydraulically, using specialized software. When the distribution line was created, nodes of the points of interest and extra nodes were established to check the pressure in the static and dynamic model and speeds. Additionally, the calculation of consumption flows was carried out for each section of pipe and additionally the maximum hourly flow, maximum daily flow and average flow. The flow rate of the pipe leaving the storage tank that contained a volume of 40 m^3 was carried out, in order to obtain a consumption curve to identify possible failures in the network. Lastly, improvements were proposed based on the results of the hydraulic evaluation, taking into account the regulations of the Metropolitan Company of Sewerage and Drinking Water of Quito (EPMAP-Q), with the creation of two plans that contain the distribution line current and the line with the proposed improvements made, which consisted of the placement of pressure regulating valves at strategic points, in order to guarantee an efficient water supply. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Quito : EPN, 2024. | es_ES |
dc.rights | openAccess | es_ES |
dc.subject | AGUA - SANEAMIENTO | es_ES |
dc.subject | HIDRÁULICA | es_ES |
dc.subject | EVALUACIÓN HIDRÁULICA | es_ES |
dc.subject | RED DE DISTRIBUCIÓN | es_ES |
dc.title | Evaluación hidráulica de las redes de distribución del sistema de abastecimiento de la comuna Chinchiloma : evaluación hidráulica de la red de distribución del barrio "Sector 3". | es_ES |
dc.type | Trabajo de Integración Curricular | es_ES |
Aparece en las colecciones: | TIC - Tecnología Superior en Agua y Saneamiento Ambiental |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
CD 14099.pdf | 6,67 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.